User Tools
support:alarm_sync_failures
This is an old revision of the document!
Author: Paddy Murphy
This wiki was created to assist if you encounter issues with Alarm Sync.
Please note that an Alarm Severity Sync should be run before an Active Alarm Sync
Run the following query on the Controller been investigated.
select id, name, technology, software_version ip_address, port, link_down, login_credentials_id, http_session_manager_configuration_id, alarm_sync_setting_id, discovered_trap_configuration_id from network_element where id = <network element id>;
Verify that none of the following values are null:
- login_credentials_id
- http_session_manager_configuration_id
- alarm_sync_setting_id
- discovered_trap_configuration_id
- software_version
support/alarm_sync_failures.1709901025.txt.gz · Last modified: 2024/03/08 12:30 by 10.91.120.100