Author: Paddy Murphy This wiki was created to assist if you encounter issues with Alarm Sync. Please note that an Alarm Severity Sync should be run before an Active Alarm Sync ===== Troubleshooting Checklist ===== - Verify that you can login into the Controller and successfully reach a landing page with data. Some Controllers can only be accessed through a [[support:tunneling|tunnel]] - Is the Controller link down? [[onboarding:snmpmanager:introduction_to_link_polling_and_types|link down functionality]] - Is the software version supported. -- check supported technologies & software versions here [[https://docs.google.com/spreadsheets/d/1MWddwE7AitjY1khgNXU6USs8bVP54W5UKb-Byxps4qo/edit#gid=2021934505 | here]] - Are the assigned login credentials correct and not null at the controller level? [[support:login_credentials_for_controllers|Controller Login values]] - Is the correct IP address assigned to the controller? - Does the Controller require a port number i.e. 8080? This can be verified by logging into controller. - Is the correct discovered trap configuration value assigned to the Controller and Child elements? - Is the correct http session manager configuration assigned to the controller? - Is the correct alarm sync configuration assigned to the controller? Run the following query on the Controller been investigated. select id, name, technology, software_version ip_address, port, link_down, login_credentials_id, http_session_manager_configuration_id, alarm_sync_setting_id, discovered_trap_configuration_id from network_element where id = ; Verify that none of the following values are null: * ip_address * login_credentials_id * http_session_manager_configuration_id * alarm_sync_setting_id * discovered_trap_configuration_id * software_version ===== Common Sync Errors ===== === URL path or OID did not specified === * Missing or incorrect disabled_alarm_parse_script_id in assigned alarm sync setting * verify that the script assigned in retrieve_path_script_id contains a valid entry for disabled alarm. * If technology does not support disabled alarms assign a "NO DISABLED ALARMS" script in alarm sync setting === Failed to connect/login to ... === * Missing login_credentials_id * Incorrect login_credentials_id assigned to controller. * UI issues on the controller login page, confirm & report to customer === TimeoutException : time out after retries === * Incorrect login_credentials_id assigned to controller. * If error message contains OID check if snmp values are correct and manually run command * UI issues on the controller login page, confirm & report to customer === SocketTimeoutException : Read timed out === * Missing login_credentials_id * Incorrect login_credentials_id assigned to controller. === disabledAlarms = null, discoveredAlarms = 1 === * Confirm that alarm severity sync has run * Verify that only one ALARM_SEVERITY_SYNC is assigned to controller, remove duplicates. select * from network_element_sync_setting where job_type = 'ALARM_SEVERITY_SYNC' and network_element_id = ; === No discovered trap configuration for ... === * The discovered_trap_configuration_id is missing for referenced element