Previous revision
support:alarm_sync_failures [2024/03/08 12:28] 10.91.120.100support:alarm_sync_failures [2025/01/08 17:27] (current) – [Common Sync Errors] 10.91.120.100
Line 5: Line 5:
 Please note that an Alarm Severity Sync should be run before an Active Alarm Sync Please note that an Alarm Severity Sync should be run before an Active Alarm Sync
  
 +===== Troubleshooting Checklist =====
 +
 +  - Verify that you can login into the Controller and successfully reach a landing page with data. Some Controllers can only be accessed through a [[support:tunneling|tunnel]]
 +  - Is the Controller link down?  [[onboarding:snmpmanager:introduction_to_link_polling_and_types|link down functionality]]
 +  - Is the software version supported. -- check supported technologies & software versions here [[https://docs.google.com/spreadsheets/d/1MWddwE7AitjY1khgNXU6USs8bVP54W5UKb-Byxps4qo/edit#gid=2021934505 | here]]
 +  - Are the assigned login credentials correct and not null at the controller level? [[support:login_credentials_for_controllers|Controller Login values]]
 +  - Is the correct IP address assigned to the controller?
 +  - Does the Controller require a port number i.e. 8080? This can be verified by logging into controller.
 +  - Is the correct discovered trap configuration value assigned to the Controller and Child elements?
 +  - Is the correct http session manager configuration assigned to the controller?
 +  - Is the correct alarm sync configuration assigned to the controller?
  
 Run the following query on the Controller been investigated. Run the following query on the Controller been investigated.
     select id, name, technology, software_version ip_address, port, link_down, login_credentials_id, http_session_manager_configuration_id, alarm_sync_setting_id, discovered_trap_configuration_id  from network_element where id = <network  element id>;     select id, name, technology, software_version ip_address, port, link_down, login_credentials_id, http_session_manager_configuration_id, alarm_sync_setting_id, discovered_trap_configuration_id  from network_element where id = <network  element id>;
 +    
 +Verify that none of the following values are null:
 +  * ip_address
 +  * login_credentials_id
 +  * http_session_manager_configuration_id
 +  * alarm_sync_setting_id
 +  * discovered_trap_configuration_id
 +  * software_version
 +
 +===== Common Sync Errors  =====
 +
 +=== URL path or OID did not specified ===
 +  * Missing or incorrect disabled_alarm_parse_script_id in assigned alarm sync setting
 +  * verify that the script assigned in retrieve_path_script_id contains a valid entry for disabled alarm.
 +  * If technology does not support disabled alarms assign a "NO DISABLED ALARMS" script in alarm sync setting
 +
 +=== Failed to connect/login to ... ===
 +  * Missing login_credentials_id
 +  * Incorrect login_credentials_id assigned to controller.
 +  * UI issues on the controller login page, confirm & report to customer
 +
 +=== TimeoutException : time out after retries ===
 +  * Incorrect login_credentials_id assigned to controller.
 +  * If error message contains OID check if snmp values are correct and manually run command
 +  * UI issues on the controller login page, confirm & report to customer
 +
 +=== SocketTimeoutException : Read timed out ===
 +  * Missing login_credentials_id
 +  * Incorrect login_credentials_id assigned to controller.
 +
 +=== disabledAlarms = null, discoveredAlarms = 1 ===
 +  * Confirm that alarm severity sync has run
 +  * Verify that only one ALARM_SEVERITY_SYNC is assigned to controller, remove duplicates.
 +
 +  select * from network_element_sync_setting where job_type = 'ALARM_SEVERITY_SYNC'  and 
 +  network_element_id = <network  element id>;
 +  
 +=== No discovered trap configuration for ... ===
 +  * The discovered_trap_configuration_id is missing for referenced element
 +
support/alarm_sync_failures.1709900916.txt.gz · Last modified: 2024/03/08 12:28 by 10.91.120.100