 Author: Paddy Murphy Author: Paddy Murphy
  
-This wiki was created to assist if you encounter issues with Alarm Sync+This wiki was created to assist if you encounter issues with Alarm Sync
 + 
 +Please note that an Alarm Severity Sync should be run before an Active Alarm Sync 
 + 
 +===== Troubleshooting Checklist ===== 
 + 
 +  - Verify that you can login into the Controller and successfully reach a landing page with data. Some Controllers can only be accessed through a [[support:tunneling|tunnel]] 
 +  - Is the Controller link down?  [[onboarding:snmpmanager:introduction_to_link_polling_and_types|link down functionality]] 
 +  - Is the software version supported. -- check supported technologies & software versions here [[https://docs.google.com/spreadsheets/d/1MWddwE7AitjY1khgNXU6USs8bVP54W5UKb-Byxps4qo/edit#gid=2021934505 | here]] 
 +  - Are the assigned login credentials correct and not null at the controller level? [[support:login_credentials_for_controllers|Controller Login values]] 
 +  - Is the correct IP address assigned to the controller? 
 +  - Does the Controller require a port number i.e. 8080? This can be verified by logging into controller. 
 +  - Is the correct discovered trap configuration value assigned to the Controller and Child elements? 
 +  - Is the correct http session manager configuration assigned to the controller? 
 +  - Is the correct alarm sync configuration assigned to the controller? 
 + 
 +Run the following query on the Controller been investigated. 
 +    select id, name, technology, software_version ip_address, port, link_down, login_credentials_id, http_session_manager_configuration_id, alarm_sync_setting_id, discovered_trap_configuration_id  from network_element where id = <network  element id>; 
 +     
 +Verify that none of the following values are null: 
 +  * ip_address 
 +  * login_credentials_id 
 +  * http_session_manager_configuration_id 
 +  * alarm_sync_setting_id 
 +  * discovered_trap_configuration_id 
 +  * software_version 
 + 
 +===== Common Sync Errors  ===== 
 + 
 +=== URL path or OID did not specified === 
 +  * Missing or incorrect disabled_alarm_parse_script_id in assigned alarm sync setting 
 +  * verify that the script assigned in retrieve_path_script_id contains a valid entry for disabled alarm. 
 +  * If technology does not support disabled alarms assign a "NO DISABLED ALARMS" script in alarm sync setting 
 + 
 +=== Failed to connect/login to ... === 
 +  * Missing login_credentials_id 
 +  * Incorrect login_credentials_id assigned to controller. 
 +  * UI issues on the controller login page, confirm & report to customer 
 + 
 +=== TimeoutException : time out after retries === 
 +  * Incorrect login_credentials_id assigned to controller. 
 +  * If error message contains OID check if snmp values are correct and manually run command 
 +  * UI issues on the controller login page, confirm & report to customer 
 + 
 +=== SocketTimeoutException : Read timed out === 
 +  * Missing login_credentials_id 
 +  * Incorrect login_credentials_id assigned to controller. 
 + 
 +=== disabledAlarms = null, discoveredAlarms = 1 === 
 +  * Confirm that alarm severity sync has run 
 +  * Verify that only one ALARM_SEVERITY_SYNC is assigned to controller, remove duplicates. 
 + 
 +  select * from network_element_sync_setting where job_type = 'ALARM_SEVERITY_SYNC'  and  
 +  network_element_id = <network  element id>; 
 +   
 +=== No discovered trap configuration for ... === 
 +  * The discovered_trap_configuration_id is missing for referenced element
  
support/alarm_sync_failures.1709899893.txt.gz · Last modified: 2024/03/08 12:11 by 10.91.120.100